SECURSTOR ASTRA ES 75
Figure 11: Replacing a Power Supply
Replacing a Cooling Unit Blower
The blower (scroll fan) in each cooling unit is replaced as an individual part. No tools are required for this
procedure.
Remove and Replace a Blower
To replace a blower:
1. Verify that the Fan LED is amber or red.
Fan LED
Figure 12: Fan LED
2. Press the release button and pull the handle downward.
3. Pull the cooling unit out of the Astra ES enclosure.
Figure 13: Removing a cooling unit from the enclosure
4. Loosen the thumbscrew. A retainer keeps the thumbscrew in place.